Fuel Tank Air Filter Leak Tester

This test rig is designed to evaluate the performance of the air filter used in fuel tank filler necks.
The following test items can be tested on this equipment.

▪︎ Leakage Test
▪︎ Flow Resistance Test
▪︎ Filter Efficiency Test
▪︎ CCV Valve Current Test

SPECIFICATION

■ Specifications are subject to change to improve performance.
Power Consumption10kW
Leak DetectorATEQ, F620 (Static pressure)
Vacuum & Flow Range0 ~ -75kPa / 20 ~ 200 lpm (ORION KRF-15)
Flow Range30 Liter/min or Customer Demand
Dust Feeder0.2 ~ 0.3g/min, 4~30g/min (Option)
Power Supply220V, 3 Phase, 60Hz

MSFT YouTube